Load-bearing wall removal and steel beam design

Opening up a kitchen and dining room, or creating an open-plan ground floor? We design the steel beam, padstones and temporary propping so a load-bearing wall can be removed safely and with building control approval.

Load-bearing wall removal

What we provide

  • Site visit to confirm whether the wall is load-bearing and what it supports
  • Steel beam (RSJ) sizing and connection design
  • Padstone and bearing design on the walls or piers either side
  • Temporary propping details (needles and props) for your builder
  • Checks on existing foundations where loads increase
  • Calculations and drawings ready for building control

When you need it

If a wall supports floors, the roof, another wall above or a chimney, removing it means that load has to be carried by a new beam. Building control needs calculations from a competent engineer before work starts, and your builder needs a clear drawing showing the beam size, bearings and propping.

Signs a wall may be load-bearing

  • Floor joists above run across the wall and rest on it
  • There is a wall directly above it on the floor above
  • It contains, or sits next to, a chimney breast
  • It is a thick brick or block wall rather than a thin stud partition
  • It runs through the middle of the house, parallel to the front and back walls

None of these signs is proof on its own. Some partitions carry load and some solid walls do not, so the wall should always be checked by an engineer before anything is removed.

What happens when a load-bearing wall is removed

  • 1. Survey and design: we visit, confirm what the wall supports, and design the beam, padstones and propping
  • 2. Building control: you or your builder submit our calculations and drawings for approval
  • 3. Party wall notice: served on your neighbour if the beam bears on a shared wall
  • 4. Temporary support: the builder installs props and needles to hold up the structure above
  • 5. Beam installation: the wall is taken out and the steel beam is placed on its padstones
  • 6. Inspection and finishing: building control inspects, and the steel is fire-protected and boxed in

Steel beams, padstones and fire protection

The new beam sits on padstones, usually concrete or engineering brick, which spread the load safely into the walls or piers below. Steelwork supporting floors in a house normally needs fire protection under Part B of the Building Regulations, commonly fire-rated plasterboard or intumescent paint. Our drawings set out the beam size, bearing lengths, padstone sizes and propping so the steel can be ordered straight away.

Removing a chimney breast

Taking out a chimney breast also means supporting the chimney above it, usually with a steel beam, or in some cases with gallow brackets where building control accepts them. Our project at Brownlow Road, Berkhamsted included removing a chimney stack at ground floor level.

Knock-throughs across Surrey and London

Opening up the ground floor is one of the most common jobs we design, particularly in Victorian, Edwardian and 1930s homes in areas such as Epsom and Ewell, Sutton, Wimbledon and Kingston. Wondering about costs? Read how much a structural engineer costs, or see what goes into our structural calculations.

What you receive

A site visit by an experienced engineer, clear calculations and drawings ready for building control, and answers to building control and builder queries about our design.

How it works

  1. Get in touchCall, WhatsApp, email or use the form. We reply within 24 hours.
  2. Approve your quoteYou see exactly what is included before any work starts.
  3. Site inspectionAn engineer visits, usually within 3 to 5 working days.
  4. Design deliveredCalculations and drawings, typically 10 to 12 working days later.

Frequently asked questions

How do I know if a wall is load-bearing?

Clues include floor joists resting on it, a wall directly above it on the next floor, or a chimney breast built into it. Appearances can mislead, so an engineer should confirm it on site before anything is removed.

Do I need building control approval to remove a load-bearing wall?

Yes. Removing a load-bearing wall is structural work under the Building Regulations, so you need building control approval, normally supported by structural calculations and drawings.

Do I need a party wall agreement?

If the new beam bears on, or is cut into, a wall shared with a neighbour, the Party Wall etc. Act 1996 is likely to apply and your neighbour must be notified before work starts.

How quickly can you provide the calculations?

We reply within 24 hours on working days, usually visit within 3 to 5 working days, and typically deliver calculations and drawings 10 to 12 working days after the visit. Simple beams can often be completed sooner.

Popular areas: structural engineer in Epsom, structural engineer in Guildford, structural engineer in Woking, structural engineer in Kingston, structural engineer in Wimbledon, structural engineer in Croydon, structural engineer in Hitchin, structural engineer in St Albans, structural engineer in London. See all areas we cover →

Ready to start your project?

Send us your drawings or a few photos and we will reply within 24 hours on working days.

5-star rated on Google – read our reviews